RTM8248-GSM
RTM-FEM-GSM
RTM-RTR-GSM
RTM8248-GSM
|
CONTROL UNIT for Section Switch Remote Control (SSRC) and DSP
|
Purpose: |
Unit RTM8428-GSM performs scanning of analog and discrete values and operating power blocks of SSRC, DSP and similar devices. |
 |
Power supply: |
24 V DC (optionally 12 V DC, 48 V DC) ±10 % |
Consumption: |
a) in no transmission state: |
120 mA (230 mA, 60 mA) |
b) in transmission state: |
330 mA (650 mA, 170 mA) |
|
Storage temperature: |
-40 °C to +80 °C |
Operation temperature: |
-30 °C to +65 °C |
Humidity: |
0 % to 95 % |
Communication with superior system: |
GPRS/GSM – APN – LAN (INTRANET) |
Communication protocols: |
IEC 870-5-101
IEC 870-5-104 |
Digital inputs: |
|
Number of bits: |
24 |
Galvanic isolation: |
disruptive strength 2,5 kV |
ON voltage level: |
12 V to 110 V (configurable ON and OFF ranges) |
ON current level: |
1 mA to 20 mA (configurable ON and OFF ranges) |
Signal type: |
any compound of single and double bit for total amount of bits |
Time processing: |
with adjustable time filter which determines minimal acceptable duration of changes |
Digital relay outputs: |
|
Number of outputs: |
8 |
Galvanic isolation: |
disruptive strength 1,5 kV |
Max. current loading: |
3 A |
Max. switching voltage: |
30 V DC (optionally 48 V DC) |
Signal type: |
– state
– bistable
– pulse (configurable pulse duration for each output) |
Analog inputs: |
|
Number of inputs: |
7 |
Inputs (configurable for each channel): |
– DC voltage, negative pole on GND
range 0 V to 5 V (optionally 0 V to 10 V)
– DC current, negative pole on GND
range 0 mA to 5 mA (optionally 0 mA to 20 mA) |
Accurate class: |
2,5 (optionally 1,5) |
Resolution: |
12 bits |
Time processing: |
– periodic
– based on changes with filtering (configurable delta criterion for each input) |
Weight: |
550 g |
Dimension: |
length 225 mm |
|
width 100 mm |
|
height 40 mm with antenna connector and DIN rail mounting bracket |
RTM FEM GSM
|
MANAGING TELEMETRIC MODUL
|
Purpose: |
Unit RTM-FEM-GSM is a control telemetry module that communicates with a superior system via GSM / GPRS. For data communication protocol is done IEC 60870-5 -
104 Unit RTM-FEM-GSM includes optional up to 3 serial interfaces for communication with subordinate system. The unit RTM-FEM-GSM is possible using these serial interfaces to connect devices containing digital and analog inputs and outputs, so. expanders, devices communicating protocol IEC 60870-5-101 or any device using the transparent serial channel through TCP / IP. Unit RTM-FEM-GSM also includes an Ethernet interface for connecting subdivisional system using this interface and protocol IEC 60870-5-104.
|  |
Power supply: |
12 V DC/24V DC +/- 10% |
Consumption: |
a) in no transmission state @ 12 V: |
350 ma |
b) in active mode GSM 900 @12V: |
700 mA |
b) in active mode GSM 1800 @12V: |
700 mA |
|
Storage temperature: |
-40 °C až +80 °C |
Operation temperature: |
-30 °C až +65 °C |
Humidity: |
0 % až 95 % |
Communication with superior system: |
GPRS/GSM |
Communication protocols: |
IEC 870-5-101
IEC 870-5-104 |
Interfaces: |
|
Serial interfaces: |
|
P1: |
RS232/RS422/RS485 , RS232 full UART |
P2: |
RS232/RS422/RS485 , RS232 full UART |
P3: |
RS232/RS422/RS485 , RS232 full UART |
Ethernet interface: |
|
E1: |
10/100 Mb/s FULL/HALF DUPLEX |
Console: |
|
Interface: |
serial special |
Parameters: |
115200 Bb, 8 bit, 1 stopbit, parity none |
Weight: |
370 g |
Dimension: |
length 160 mm |
|
width 100 mm |
|
height 40 mm with antenna connector and DIN rail mounting bracket |
RTM RTR GSM
|
MANAGING TELEMETRIC MODUL
|
Purpose: |
Unit RTM-RTR-GSM is a control telemetry module that communicates with a superior system via GSM / GPRS. For data communication protocol is done IEC 60870-5 -
104 Unit RTM-RTR-GSM includes optional up to 2 serial interfaces for communication with subordinate system. The unit RTM-RTR-GSM is possible using these serial interfaces to connect devices
containing digital and analog inputs and outputs, so. expanders, devices communicating protocol IEC 60870-5-101 or any device using the transparent serial channel through TCP / IP.
Unit RTM-RTR-GSM also includes an 2 Ethernet interfaces for connecting subdivisional system using this interface and protocol IEC 60870-5-104.
|  |
Power supply: |
12 V DC/24V DC +/- 10% |
Consumption: |
a) in no transmission state @ 12 V: |
350 ma |
b) in active mode GSM 900 @12V: |
700 mA |
b) in active mode GSM 1800 @12V: |
700 mA |
|
Storage temperature: |
-40 °C až +80 °C |
Operation temperature: |
-30 °C až +65 °C |
Humidity: |
0 % až 95 % |
Communication with superior system: |
GPRS/GSM |
Communication protocols: |
IEC 870-5-101
IEC 870-5-104 |
Interfaces: |
|
Serial interfaces: |
|
P1: |
RS232/RS422/RS485 , RS232 full UART |
P2: |
RS232/RS422/RS485 , RS232 full UART |
Ethernet interfaces: |
|
E1: |
10/100 Mb/s FULL/HALF DUPLEX |
E2: |
10/100 Mb/s FULL/HALF DUPLEX |
Console: |
|
Interface: |
serial special |
Parameters: |
115200 Bb, 8 bit, 1 stopbit, parity none |
Weight: |
285 g |
Dimension: |
length 120 mm |
|
width 100 mm |
|
height 40 mm with antenna connector and DIN rail mounting bracket |
|
 |